Power Cable
tested
CYABY(F) ,NYBY  , Rated voltage : 0,6/1 KVConstruction :1. Solid or multiwire copper conductor , 2. PVC insulation , 3. Filler , 4.Armour of steel tape , 5.Outer PVC sheath.Application: Power cablefor fixed outdoor installations in ground or in concrete. ..
0Ron
Ex Tax:0Ron
Power Cable
tested
CYEAbY(F)  Tensiunea nom.: 0,6/1 KVConstructii:1. Solid or multiwire copper conductor 2. PVC insulation 3. Filler ,4.-Copper foil screen,5.Inner PVC sheath , 6.Armour of steel tape 7.Outer PVC sheath.Application: Power cablefor fixed outdoor installations in ground..
0Ron
Ex Tax:0Ron
Power Cable
tested
CYY , CYY-F , NYY , YVV  Tensiunea nom.: 0,6/1 KVConstructii:1. Solid or multiwire copper conductor 2. PVC insulation 3. Filler ,4.Outer PVC sheath.Application: Power cablefor fixed outdoor installations in ground or in concrete. ..
0Ron
Ex Tax:0Ron
Power Cable
tested
ACYY , NAYYConstruction 1 Conductor: aluminum (1,2 class)2 Core Insulation: PVC3 Sheath: PVC Technical specification Rated voltage: 300/500 V Min. perm. temp. – with installation and handling: -5 °C ..
0Ron
Ex Tax:0Ron
Power Cable
tested
Construction1. Conductor: aluminum (1,2 class).2. Core Insulation: PVC.3.Filler: PVC.4. Screen: aluminum or copper tape.5. Sheath: PVC.Technical specificationRated voltage: 300/500 VMin. perm. temp.– with installation and handling: -5 °C– storage: –40 °CMax. perm. storage temp.: +40 °COperating temp..
0Ron
Ex Tax:0Ron
Power Cable
tested
ACYABY(F) , NAYBYConstruction1 Conductor: aluminum (1,2 class)2 Core Insulation: PVC3 Filler4 Armour: steel tapes5 sheath: PVCTechnical specificationRated voltage: 300/500 VMin. perm. temp.– with installation and handling: -5 °C– storage: –40 °CMax. perm. storage temp.: +40 °COperating temperature: ..
0Ron
Ex Tax:0Ron
Signalling and control cables
tested
YSLYConstruction1.Class 5 Fine Stranded Bare Copper , 2.Insulated conductors in concentric layers 3.PVC sheathApplication :Control and signal transmittal  in power generation and supply facilities. The cables can be installed in open or confined areas, underground, in sewers, in concr..
0Ron
Ex Tax:0Ron
Signalling and control cables
tested
LIYY  0.6 / 1 kVConstruction:1 Conductor: copper flexible (3 – 5 class);2 Core Insulation: PVC;3 Sheath: PVCApplication:Сables are used during stationary installation in electrical appliances, alternating-current equipment with nominal voltage of 600 V or direct-current switchgears with nominal..
0Ron
Ex Tax:0Ron
Signalling and control cables
tested
LIY(St)Y  0.6 / 1 kVConstruction:1 Conductor: copper flexible (3 – 5 class);2 Core Insulation: PVC;3.Screen of AlPet foil and drain wire, 4.Sheath: PVCApplication:Сables are used during stationary installation in electrical appliances, alternating-current equipment with nominal voltage of ..
0Ron
Ex Tax:0Ron